2009

Mario Jirschik, Herzzentrum Bad Krozingen, Germany
"Bubble elimination in different oxygenators - an In Vivo Study"

Jan Schaarschmidt, University of Leipzig, Heart Center, Germany
"Clinical Evaluation of the new BMU 40TM In-Line Blood Gas Monitor"

Dirk Troitzsch, University of Applied Sciences, Köthen, Germany
"Influence of perfusion flow and temperature on cerebral hemodynamics and oxygen saturation in neonates during cardiopulmonary bypass"

Frode Kristiansen, Rikshospitalet University Hospital, Oslo, Norway
"Wavelength selection for accurate oximetry during cardiopulmonary bypass"

Michael Wechner, Abiomed Europe; Department of Clinical Development and Training, Germany
"Evaluation Synthesis (Sorin Biometica) versus Compactflo (Dideco) – Integrated meets Established"

Susie Lindegaard, Odense University Hospital, Denmark
"A randomized comparative study of two calculations of different doses for heparin and protamine administration. And the effect on postoperative bleeding after open cardiac surgery"

Mohamed Ali Nuur, Odense University Hospital, Denmark
"Investigation of Haemoglobin quality of shed mediastinal blood"

Bente Øvrebø, Haukeland University Hospital, Bergen, Norway
Will use of the "mini cardiopulmonary bypass" lead to higher levels of haemoglobin and less bleeding compared with conventional bypass?"

Hege Eikemo, Haukeland University Hospital, Bergen, Norway
"Will use of a mini-bypass circuit reduce fluid volume postoperatively compared with conventional bypass"

Linda Önsten, Sahlgrenska University Hospital, Gothenburg, Sweden
"Platelet aggregability before and after cardiopulmonary bypass"

Maria Kalabic, Sahlgrenska University Hospital, Gothenburg, Sweden
"Temporal changes in fibrinogen plasma concentration and the acute phase response after cardiac surgery"

William Bundgaard, Aalborg University Hospital, Denmark
"Best Cardiac Output during Cardiopulmonary Bypass"

Magnus Rosén, Linköping University Hospital, Sweden
"Is there a correlation between the amount of suction - (shed) blood and the immunological response?"

Jon Bering Kristensen, Aarhus University Hospital, Skejby, Denmark
"Assessment of bubble transgression with Vacuum-Assisted venous drainage, an in vitro comparative no flow state study of 2 oxygenators"

Mikael Kanetoft, Örebro University Hospital, Sweden
"Skillnader mellan inställt och uppmätt flöde med rollerpumpar - en in vitro jämförelse mellan tre metoder att ställa ocklusion"

Anne Louise Bellaiche, Aarhus University Hospital, Skejby, Denmark
"Comparison of the performance of the CDI 500 with and without gas calibration"

Vidar Y. Andersen, Oslo University Hospital, Norway
"Comparison of extracorporeal surfaces with heparin and non-heparin coating with respect to inflammatory reaction"